Ordering stainless steel pipe in South Africa comes down to three things: size, schedule and wall thickness. They are closely linked, and confusing them is one of the most common causes of incorrect orders, delays and costly rework on site. Stainless steel grade of course, is another big factor.

This guide explains how stainless steel pipe is sized, what a “schedule” really means, and how to read a wall thickness chart, so you can specify the right pipe first time.

How stainless steel pipe is sized

Pipe is sized by Nominal Pipe Size (NPS) in inches, or Nominal Bore (DN) in millimetres. These are labels, not exact measurements. A 2″ (DN50) pipe does not measure 50mm or 2 inches anywhere.

What stays fixed is the outside diameter (OD). A 2″ pipe has an OD of 60.33mm whether it is thin walled or heavy walled. Flanges, fittings and supports are made to fit that OD, which means a pipe in any schedule connects to the same fittings.

For pipe up to 12″, the OD is always larger than the nominal size. From 14″ upwards, the NPS and the OD in inches are the same number.

What “pipe schedule” means

The schedule is a label for wall thickness. In general, the higher the schedule number, the thicker the wall, and the greater the pipe’s ability to handle pressure.

Schedule is not a fixed thickness. It is relative to the pipe size, so a 2″ SCH40S and a 6″ SCH40S have different wall thicknesses (3.91mm and 7.11mm). The schedule tells you the wall relative to that size.

Because the OD stays the same, a thicker wall reduces the internal diameter. This affects flow capacity, so it matters when sizing a system.

The standards: ASME B36.19 and B36.10

Two ASME standards cover most stainless steel pipe supplied in South Africa.

ASME B36.19 covers stainless steel pipe and uses an “S” suffix:

  • SCH5S (5S)
  • SCH10S (10S)
  • SCH40S (40S)
  • SCH80S (80S)

ASME B36.10 covers the schedules without the “S”, including SCH10, SCH20, SCH30 and Standard (STD). It is the standard used for carbon steel pipe, and is also referenced for stainless steel pipe, particularly in larger sizes.

The main stainless steel pipe schedules

SCH5S (5S):

  • Thinnest wall in the stainless range
  • Lightweight and cost-effective
  • Suited to low-pressure and non-critical applications

SCH10S (10S):

  • Thin wall for low to medium pressure
  • Common in water systems, food and beverage processing, and general industrial use
  • A good balance between strength and cost

SCH40S (40S):

  • Medium wall thickness
  • Suited to moderate-pressure applications
  • Widely used across industrial piping systems

SCH80S (80S):

  • Heavy wall for higher-pressure applications
  • Greater strength and durability
  • Common in chemical processing, power generation and demanding industrial environments

Stainless steel is strong and corrosion resistant, so thinner walls such as 5S and 10S are used far more often in stainless than in carbon steel piping. That is why the “S” schedules exist as a separate series.

Stainless steel pipe wall thickness and weight chart

Euro Steel Pipe supplies seamless and welded austenitic stainless steel pipe from ⅛” to 36″ (DN6 to DN900). The chart below shows a selection of common sizes. Wall thickness is in mm, followed by weight in kg per metre.

 

 

NPSDNOD (mm)5S10S40S80S
Wall Thickness (mm) / Weight (kg/m)
1/8″–10.29–1.24 / 0.2811.73 / 0.3712.41 / 0.476
¼”813.72–1.65 / 0.4992.24 / 0.6443.02 / 0.809
3/8″1017.15–1.65 / 0.6402.31 / 0.8583.20 / 1.100
½”1521.341.65 / 0.8142.11 / 1.0162.77 / 1.263.73 / 1.62
1″2533.401.65 / 1.3122.77 / 2.1253.38 / 2.544.55 / 3.23
2″5060.331.65 / 2.4242.77 / 3.9923.91 / 5.295.54 / 7.47
3″8088.902.11 / 4.5853.05 / 6.5575.49 / 11.487.62 / 15.25
4″100114.302.11 / 5.9453.05 / 8.4966.02 / 16.348.56 / 22.29
6″150168.282.77 / 11.5143.40 / 14.0377.11 / 28.7210.97 / 42.52
8″200219.082.77 / 15.0493.76 / 20.3348.18 / 43.2712.70 / 64.57
12″300323.853.96 / 31.8064.57 / 36.589.53 / 75.0412.70 / 97.36
16″400406.404.19 / 42.354.78 / 48.079.53 / 94.7012.70 / 125.20
24″600609.605.54 / 84.106.35 / 96.2159.53 / 143.2012.70 / 181.82

Reading the chart

Take a 2″ pipe. The wall goes from 1.65mm in 5S to 5.54mm in 80S, more than three times as thick. The weight rises from 2.42 kg/m to 7.47 kg/m. The outside diameter stays at 60.33mm throughout.

Weight matters beyond cost. It affects handling, lifting, transport and the load on supports, particularly on large-diameter lines.

Download the full stainless steel pipe size chart (PDF)

– link https://www.eurosteel.co.za/wp-content/uploads/2025/03/Stainless-Steel-Pipe.pdf

ASME B36.10 schedules: SCH10, SCH20, SCH30 and Standard

For larger pipe, you will also see the B36.10 schedules:

  • SCH10: identical to 10S up to 12″. From 14″ it is a heavier wall of 6.35mm (14″ to 24″), rising to 7.92mm (26″ to 36″)
  • SCH20: available from 8″ upwards, for example 6.35mm on an 8″ pipe and 12.70mm on a 30″ pipe
  • SCH30: available from 8″ upwards, for example 7.04mm on an 8″ pipe and 15.88mm on a 36″ pipe
  • Standard (STD): 9.53mm wall on all sizes from 12″ to 36″

These suit larger-diameter lines where the extra wall is needed for the application.

How to choose the right schedule

The right schedule depends on:

  • Operating pressure: higher pressure calls for a thicker wall
  • Temperature: high operating temperatures reduce a pipe’s pressure rating
  • Corrosion environment: aggressive media or coastal conditions may call for extra wall allowance
  • Flow requirements: a thicker wall means a smaller internal bore
  • Weight and support: heavier pipe needs stronger supports
  • Budget: a heavier schedule uses more material and costs more

Schedule is only part of the specification. The stainless steel grade is just as important, and for guidance on grade selection we can advise but also refer to SASSDA – the South African Stainless Steel Development Association.

Checklist before you order

To get an accurate quote, have the following ready:

  1. Grade
  2. Nominal size (NPS or DN)
  3. Schedule (5S, 10S, 40S, 80S, or a B36.10 schedule)
  4. Seamless or welded
  5. Quantity
  6. Delivery location
  7. Any certification requirements

Frequently asked questions

Does a higher schedule mean a bigger pipe?
No. The outside diameter stays the same. A higher schedule means a thicker wall and a smaller internal bore.

Is SCH40 the same as SCH40S?
For sizes up to 10″, the wall thicknesses are the same. They are separate designations under different standards, and the “S” series is the one made for stainless steel pipe.

What is the difference between NPS and DN?
NPS is the inch-based size and DN is the metric equivalent. For example, 2″ is DN50 and 4″ is DN100.

Can I use the same fittings on different schedules?
Fittings are matched to the OD, so they fit across schedules. Buttweld fittings should still be specified to the same schedule as the pipe so the wall thicknesses match at the weld.

Stainless steel pipe from Euro Steel Pipe

Euro Steel Pipe – a Division of Euro Steel supplies stainless steel pipe and fittings in a wide range of sizes and schedules, as well as grades, with countrywide delivery and beyond.

We also supply certain carbon steel pipes and fittings, so you can source your piping requirements from one supplier. Contact our team to find out what is available.
[Contact Euro Steel Pipe] Email – pipeco@eurosteel.co.za